Skip to content

How much energy does travel require?

Consumption measures energy per vehicle-km. Service efficiency measures passenger-km or tonne-km per unit energy. The backend aggregates consumption and the compatible load before calculating service efficiency.

From rated configurations to fleet consumption

NRCan Ratings describe tested configurations, not actual Canadian driving. Reviewed canonical families connect eligible configurations to Ontario MTO survivors or Transport Canada iZEV acquisition records. Distinct-trim medians prevent a family with many catalogue variants from receiving many copies of its empirical count. Unsupported composition uses the documented hierarchical catalogue fallback, with coverage retained.

Empirical composition and matching

Matching proceeds within a vehicle class, model year and powertrain/range cohort. Reviewed make/model descriptions connect MTO FIT_ACTIVE counts to canonical families; eligible target-year NRCan configurations provide the consumption ratings. MTO has no observed powertrain field, so gasoline-compatible catalogue configurations establish the eligible gasoline match. MTO counts must not be described as observed gasoline, HEV or electric market shares.

For PHEV and BEV cohorts, iZEV acquisition/request records supply the eligible family composition and the configured range assignment. These counts are matched to target-year ratings, including explicitly recorded proxy windows where own-year composition is insufficient. Reusing a later supported composition window for an older vintage is an assumption, not a historical registration observation. The range labels below identify model representations; they are not statements that every matched vehicle has exactly that rated range.

Within each supported family, distinct eligible trims first produce a median consumption. The family's empirical count is then allocated once to that median. Class consumption averages these family medians using normalized count weights; outer size-class weights subsequently form the car or light-truck cohort. Where composition cannot support a match, the documented distinct-trim, family and cohort medians remain visible alongside the coverage denominator.

Gasoline car composition matched to NRCan consumption

Figure ldv-eff-2-gasoline. The car view compares eligible catalogue families, matched empirical descriptions, the catalogue fallback median and the production estimate within each size class/model year. Marker sizes show count weights, not catalogue frequency.

PHEV35 car composition matched to NRCan consumption

Figure ldv-eff-2-phev-35-miles. The same matching view for the PHEV35 car representation retains iZEV composition, range assignment and total MJ/vehicle-km after charge-depleting/charge-sustaining accounting.

BEV300 car composition matched to NRCan consumption

Figure ldv-eff-2-bev-300-miles. The BEV300 car view shows which observed descriptions support the representative cohort and how their count-weighted estimate differs from the catalogue median. It does not establish full-market or surviving-fleet coverage of incentive records.

Asterisks mark ratings after the 2023 production projection anchor. These later catalogue and composition observations provide a diagnostic comparison. Production uses its 2023 anchor and ATB relative changes for 2024 onward.

Assumption: composition counts proxy travel weights

Family, size-class, annual-cohort and range weights have different meanings. Within a NRCan CEUD class, using count weights also assumes a common annual distance across families. Transport Canada iZEV incentive eligibility and acquisition/request timing do not make its records a census of sales or surviving stock.

For normalized weights \(w_i\), consumption \(c_i\) in MJ/vehicle-km and matched occupancy or payload \(\ell_i\), the service efficiency is

\[\bar c=\sum_iw_i c_i,\qquad \bar\ell=\sum_iw_i\ell_i,\qquad \eta=\frac{\bar\ell}{\bar c}.\]

Worked example: average consumption before inversion

\(\boldsymbol{\eta}\) is passenger-km/MJ or tonne-km/MJ, numerically equal to billion service-km/PJ. For example, equally weighted consumption of 2 and 4 MJ/km gives 3 MJ/km; at two passengers, efficiency is \(2/3\) passenger-km/MJ, not the mean of \(2/2\) and \(2/4\).

Each existing road vintage weights supported annual observations by raw physical cohort stock after fuel allocation and before lifetime redistribution. Consumption and load use the same weights, with missing-year coverage recorded before renormalization. This step includes buses and motorcycles, which have different source and stock methods.

How matching changes the consumption estimate

The next four figures follow one worked example, from gasoline light-truck ratings to the consumption trajectory used for model vintages. All four steps work in energy per vehicle-km or its fuel-volume equivalent. The model applies occupancy or payload afterward to calculate service efficiency.

1. Start from the gasoline catalogue ratings

Native light-truck gasoline consumption

Figure ldv-eff-4-light-trucks-gasoline-l-100-km. Each size-class and model-year point summarizes the NRCan catalogue in its original L/100 km. The median of distinct-trim family medians gives the baseline for the matching comparison.

2. See what matching changes within each size class

Composition effect on light-truck gasoline consumption

Figure ldv-eff-7-light-trucks-gasoline. Match eligible gasoline families to Ontario MTO counts and weight the family medians within each size class. The heatmap subtracts the catalogue baseline from that estimate on a common MJ/vehicle-km basis. Blue shows lower consumption after matching and red shows higher consumption. Grey means no comparison is available. White means the estimates coincide.

3. Combine the size classes on a common energy basis

Light-truck gasoline evidence in common energy units

Figure ldv-eff-5-light-trucks-gasoline-mj-vkm. Convert the gasoline rates using the fuel's heating value and combine the size classes with their fleet weights. This gives one harmonized light-truck consumption estimate per supported year. The ATB source values share the MJ/vehicle-km axis ahead of trajectory indexing.

4. Build the gasoline vintage trajectory

Resulting light-truck gasoline vintage consumption

Figure ldv-eff-6-light-trucks-gasoline-mj-vkm. Combine the annual estimates using cohort stock weights to prepare the historical vintages. The latest observed cohort anchors the projection, and relative changes from ATB supply the future trajectory. Each prepared value represents the supported source years or projection year assigned to that model vintage.

Trucks and the observed-to-projected bridge

Assumption: fleet-year truck consumption proxies cohorts

NRCan CEUD truck consumption describes a fleet year, not a measured model-year cohort. The backend uses this as a vintage proxy. Emerging powertrains use relative NLR ATB performance against diesel; medium-truck and heavy-truck aggregation retains the weight/vocation/haul assumptions. Fuel-specific physical litres are converted with their own heating values.

For existing medium- and heavy-duty vehicles, no observed consumption series by truck model year is available. Let \(F_f(y)\) be the CEUD fleet-year rate in L/100 km, \(H_f\) the configured fuel heating value in MJ/L, and \(d\) diesel. The historical proxy assigned to cohort year \(y\) is

\[c_f(y)=F_f(y)H_f/100,\qquad c_r(y)=c_d(y)\frac{c^{ATB}_r(y_0)}{c^{ATB}_d(y_0)}.\]

The first expression applies to observed medium-truck gasoline/diesel and heavy-truck diesel. The second estimates unobserved powertrains \(r\) using the diesel fleet history and their ATB consumption ratio at the common reference \(y_0=2023\). This holds the relative powertrain advantage fixed through the historical proxy, while allowing the observed diesel fleet-year trend to vary. It does not infer individual vintage performance from an aggregate fleet rate.

The latest existing cohort then supplies a stock-weighted consumption anchor \(\bar c_r\). For projected annual years,

\[c_r^{projected}(y)=\bar c_r \frac{c^{ATB}_{q(r)}(y)}{c^{ATB}_{q(r)}(y_0)},\]

where \(q(r)=r\) except that gasoline follows the configured diesel improvement index. The anchor's payload is retained for future service efficiency. Own powertrain stock weights are used when available; the configured diesel-stock proxy and any incomplete cohort coverage remain in the audit. Truck weight, vocation and haul aggregation shape the ATB ratios rather than creating observed Canadian truck-vintage consumption.

Projection years and range variants

On the standard five-year grid, new road vintage 2025 uses the 2030 projection in prospective mode. The legacy opening-period route weights supported 2021–2025 annual consumption and load equally. Both use the 2023 aligned ratings/ATB reference for LDVs, with 2024 and 2025 calculated from ATB ratios. For LDV range variant \(r\) and projected year \(y\), consumption in MJ/vehicle-km is

\[c_r(y)=c_{anchor}\frac{c^{ATB}_r(y)}{c^{ATB}_{anchor}(y_0)}.\]

Assumption: an empirical anchor with projected relative changes

\(c_{anchor}\) is the observed class and powertrain anchor. NLR ATB supplies the relative improvement and differences across ranges. BEV300 and PHEV35 provide the reference indices for their families. Source-year policies account for sparse coverage.

Car BEV consumption bridge

Figure ldv-eff-6-cars-bev-mj-vkm. The Ontario car BEV diagnostic separates cohort evidence from indexed range trajectories in MJ/vehicle-km. The captured notebook build uses reference 2023 and explicit future ranges. The bridge is constructed from an observed anchor and relative NLR ATB changes; continuity is not validation of future performance.

Light-truck PHEV consumption before load harmonization

Figure ldv-eff-6-light-trucks-phev-mj-vkm. The light-truck PHEV view retains the energy-equivalent consumption and range representations before the final payload/occupancy division. The PHEV distance utility factor is applied to its physical components before service efficiency is calculated.

Ontario medium-truck gasoline and diesel

Ontario medium-truck gasoline and diesel consumption through historical and projected vintages

Figure ldv-eff-8-medium-trucks-incumbents-mj-vkm. Ontario's gasoline medium trucks use less energy per vehicle-km in every plotted fleet year (2000–2023) and prepared vintage (evaluated through 2050). The 2023 NRCan CEUD fleet averages are 6.33 MJ/vehicle-km for gasoline and 7.13 for diesel. Solid lines show the fleet-year proxies. Dashed lines connect each fuel's stock-weighted anchor (a circle) to its new-vintage estimates using the same relative ATB diesel improvement. Diamonds mark the consumption underlying the prepared vintages.

Heavy-truck diesel consumption before load harmonization

Figure ldv-eff-6-heavy-trucks-diesel-mj-vkm. Historical diesel consumption uses CEUD fleet-year proxies; future vintages use the observed-cohort anchor and relative ATB improvement. It is a production estimate in MJ/vehicle-km, not a measurement of consumption by truck vintage.

PHEVs need component accounting

A PHEV combines charge-depleting (CD) and charge-sustaining (CS) operation. If \(\boldsymbol{f}\) is the CD distance utility factor, its physical total consumption is

\[c=f(c_{CD,e}+c_{CD,f})+(1-f)c_{CS,f}.\]

Modeler note: distance utility and energy shares differ

Every component is in MJ/vehicle-km after explicit fuel/electricity conversion. \(\boldsymbol{f}\) is a distance fraction, not the electricity fraction of energy and not annual vehicle utilization \(\boldsymbol{u}\). Shared input-split contracts represent the resulting electric/liquid blend. Its total energy is counted once in reconciliation. The model uses a wall-energy basis for electricity. The PHEV ratings boundary remains subject to the qualification in infrastructure.

Optional NRCan CEUD energy calibration

Coverage limit: no separately reported electricity target

The registered NRCan CEUD car/light-truck fuel tables do not separately report electricity. The opt-in method therefore fits a comparable gasoline-plus-diesel boundary for cars and passenger/freight light trucks, medium trucks and heavy trucks. Heavy-truck energy is entirely diesel: its aggregate PJ total supplies the diesel target directly. Within that confirmed heavy-truck total, electricity contributes zero; this does not identify the efficiency of future electric trucks. Other reported fuels and electricity without a reported target remain visible. Missing electricity is not a measured zero.

Observation basis: 2023 values held at reference 2025

The Ontario comparison represents 2025 using the registered NRCan CEUD 2023 edition and its explicit constant-extension policy. Stock and fuel targets retain their 2023 observed values; the reconstructed fleet is aged to 2025. Annual utilization first matches the independently projected backend 2025 demand, using real GDP growth from the latest CEUD activity reference. Energy calibration preserves that projected activity. This is a reference-fleet calibration, not a new 2025 energy observation.

Source precision and numerical closure

The source reports PJ to six decimals. Independently rounded fuel components can differ from the rounded total by a few millionths of a PJ. The compatibility check uses that declared precision; fitted-energy closure uses a separate, tighter numerical tolerance. Signed residuals remain recorded. A substantive medium-truck remainder of 0.095833 PJ is retained as unresolved coverage.

For class \(\boldsymbol{c}\) and technology–vintage cohort \(\boldsymbol{v}\), reference physical stock \(\boldsymbol{N_{cv}}\), C2A \(\boldsymbol{a_c}\), utilization \(\boldsymbol{u_c}\), uncalibrated efficiency \(\boldsymbol{\eta^0_{cv}}\) and the emitted liquid-energy fraction \(\boldsymbol{\lambda_{cv}}\), predicted comparable energy in PJ is

\[E^0_c=\sum_v\frac{N_{cv}a_cu_c}{\eta^0_{cv}}\lambda_{cv},\qquad g_c=\frac{E^{CEUD,liquid}_c}{E^0_c},\qquad \eta^1_{cv}=\frac{\eta^0_{cv}}{g_c}.\]

\(\boldsymbol{N}\) is thousand surviving vehicles; \(\boldsymbol{a}\) is billion service-km per thousand vehicles per year at full utilization; \(\boldsymbol{u}\) is a dimensionless annual fraction; \(\boldsymbol{\eta}\) is billion service-km/PJ; and \(\boldsymbol{\lambda}\) is a dimensionless liquid-energy fraction. All quantities use the same reference-year physical fleet and region.

Assumption: one effective factor transfers across technologies

The degree of freedom is one dimensionless consumption multiplier per supported region/class. It preserves fleet/activity, relative consumption trajectories and the reviewed PHEV split. The same multiplier is transferred to other powertrains and future years, including electricity and hydrogen: that transfer is an explicit effective-level assumption, not a fuel-specific efficiency correction identified by NRCan CEUD. No technology-, vintage-, range- or fuel-specific correction is uniquely estimated.

Modeler note: supported calibration combinations

Historical consumption, projection anchors, future trajectories and representative range aggregation use the same adjustment. Unadjusted evidence remains available. efficiencies.ceud_energy_calibration is false by default; the comparison scenario enables it explicitly. The NRCan CEUD notebook shows targets, factors, excluded coverage, residuals and final-parameter changes. The supported combination is fixed road lifetimes and flat annual utilization; configuration validation rejects survival-curve or age-dependent combinations.

NRCan CEUD calibration closure and retained boundaries

Figure ceud-cal-1. Unadjusted and calibrated liquid energy share the left axis with the CEUD target. The striped target extension retains excluded propane and natural gas; unresolved coverage remains in the diagnostic audit. Markers on the right axis show the class consumption multipliers. Fitted closure establishes arithmetic consistency under the same fleet and activity, not independent validation of consumption or the cause of the original mismatch.

For the recorded Ontario 2025 fleet, with utilization matched to the backend's projected 2025 demand, the fitted factors are:

Class Unadjusted comparable energy (PJ) NRCan CEUD gasoline/diesel target (PJ) Consumption multiplier
Cars 151.375830 130.469305 0.861890
Passenger light trucks 241.974079 219.787701 0.908311
Freight light trucks 80.816287 71.790711 0.888320
Medium trucks 64.678631 57.445597 0.888170
Heavy trucks 160.698184 157.009704 0.977047

Diagnostic finding: the fitted consumption adjustment

Consumption falls by about 2.3–13.8% on the fitted boundary. Heavy-truck service efficiency increases by about 2.35%. Efficiency changes by the reciprocal factor, not by the same percentage. These are effective class adjustments under the stated fleet/activity assumptions, not measurements of technology-specific test-to-road bias.

Regional light-duty base-year anchor efficiency changes

Figure ceud-cal-5-ldv. Cars, passenger light trucks and freight light trucks use the same powertrain/range columns and all ten model regions. Cells show the base-year range-anchor service-efficiency change, \(\eta^1/\eta^0-1=1/g-1\), before representative aggregation. Every region uses its own fitted class factor. The common class multiplier gives emitted representatives the same percentage adjustment; the paired final-database audit separately verifies propagation.

Regional medium/heavy-duty base-year anchor efficiency changes

Figure ceud-cal-5-mhdv. Medium and heavy trucks retain the same regional layout and shared powertrain columns. The heavy-truck adjustment fits the confirmed diesel aggregate. Tooltips retain before/after range-anchor efficiencies and their units. Blank cells indicate unrepresented class/powertrain combinations rather than a zero adjustment. Historical and future relative trajectories are preserved.

Region codes preserve the backend's source boundaries: BCT combines British Columbia with the three territories; NLLAB and PEI denote Newfoundland and Labrador and Prince Edward Island. No BC-only calibration is inferred from BCT.

Confirmed boundary: heavy-truck energy is diesel

The reviewed CEUD heavy-truck energy boundary is entirely diesel. Table 36's Heavy Truck Energy Use1 (PJ) therefore supplies the complete diesel energy target. It is selected once, rather than added to a separate diesel component. Table 37's diesel L/100 km series continues to supply the historical consumption proxy; the two quantities serve different stages of the calculation. The same class-factor method now calibrates heavy-truck consumption while preserving the projected activity, physical stock and relative trajectories.

Recorded Ontario paired check

In the comparison accompanying these figures, 225 of 574 efficiency rows change by the specified class factors, including 33 heavy-truck rows. The maximum relative factor error is \(4.44\times10^{-16}\) and liquid energy closes within \(2.84\times10^{-14}\) PJ. Activity, PHEV input splits and other numerical parameters agree at the recorded tolerances. The 31 efficiency-input fingerprints match. The audit verifies final rows. Separate baseline preaggregation exports were unavailable for a byte-level comparison. See the comparison commands.